Thermometer sleeve for glass-lined reactor is the stress concentration point.

As the volume of the glass-lined reactor vessel increases, the length of the sleeve increases. The length of the inserted material and the area of ​​contact with the material will be greatly strengthened. The strength of the neck of the casing.

      Due to the different material flow patterns produced by the stirrer in the glass-lined reactor, the viscosity and the weight of the liquid are different, the bending moment sheet caused by the glass-lined thermometer casing is different, and it is difficult to calculate with a single formula. At present, the recommended pipe thickness in the glass-lined equipment general parts catalogue can only be used for paddle glass-lined stirrers, anchor glass-lined stirrers, frame glass-lined stirrers and impeller-type glass lined stirrers within 5000L in principle. Glass stirrer.

      For thermometer sleeves equipped with glass-lined reactor stirring vessels larger than 5000L, especially flat tubes or plate sleeves, the liquid blocking area is large and the bending moment is large. It is recommended to weld a thick-walled short tube with a length of 200mm~300mm under the upper flange of the glass-lined casing, and the fillet weld with the glass-lined thermometer casing flange must be full, and the transition arc radius R=10mm to ensure the thermometer casing The mechanical strength of the upper neck of the tube in use.