What are the heating methods of the glass lined reaction tank
What are the heating methods of the enamel reaction tank
The glass lined reaction tank is made of glass containing high silica lining the inner surface of a steel container, which is burnt at high temperature and firmly adheres to the metal surface to become a composite product. Then what are the heating methods for the enamel reaction tank?
1. Heating of high-temperature heat transfer oil circulation system: It is necessary to connect an external heat transfer oil boiler and connect the corresponding pipeline gate valve, especially when the processing technology regulations of more than 120 degrees and less than 150 degrees are applicable.
2. Heating of the steam circulation system: The enamel reaction tank needs to be connected to an external gas-fired steam boiler and connected to the corresponding pipeline gate valve, which is suitable for processing technology regulations with an operating temperature of less than 120 degrees.
3. Infrared heating: the infrared heating tube is brought into the jacket. The total output power of the infrared heating tube should be determined according to the processing technology regulations. The processing technology is applicable to higher processing technology requirements and higher requirements for the cleanliness of the natural environment. Natural environment.
4. Heating of the boiling water circulation system: The enamel reaction tank needs to be connected to an external gas boiler and connected to the corresponding pipeline gate valve, and the processing technology regulations of not more than 150 degrees are applicable.
5. Electric heater: The electric heating rod is brought into the jacket. The total output power of the electric heating rod should be determined according to the processing technology regulations. Generally, it is suitable for the enamel reaction tank with a small capacity, namely under 3,500 liters, and is equipped with a temperature control cabinet. .
6. In order to improve the heat transfer efficiency of the jacket, the inner fan coil can be installed in the enamel reaction tank, but because of the corrosion resistance regulations, the material requirements are higher, and it must be stainless steel pipe, PTFE pipe or titanium pipe.